Verification of National Standard of Reference Intervals for ALT, AST, ALP, GGT

Expand
  • Beijing Strong Biotechnologies, Inc. Beijing 101400, China

Received date: 2014-03-11

  Revised date: 2014-06-05

  Online published: 2014-09-03

Abstract

Objective To verify the reference intervals for ALT, AST, ALP and GGT by using native reagent. Methods The serum alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP) and γ-glutamyltansferase (GGT) in 107 healthy individuals (35 males and 72 females) aged from 20 to 62 years were detected. The results were compared with national standard to verify the reference intervals. Results The reference intervals were consistent with WS. Conclusion The WS reference intervals with Gcell reagent could be directly used in clinical laboratory.

Cite this article

HUANG Yan, WANG Tian-tian, DU Xiao-xia, JIAN Juan, ZHU Ai-hua, KANG Jia-ni, CHEN Feng-juan . Verification of National Standard of Reference Intervals for ALT, AST, ALP, GGT[J]. Labeled Immunoassays and Clinical Medicine, 2014 , 21(4) : 471 . DOI: 10.11748/bjmy.issn.1006-1703.2014.04.038